Foreach TechnologyForeach Technology
Home
Products
Applications
About Us
Contact & Partnership
简体中文EnglishEspañolFrançais한국어Русский
Home
Products
Pump SeriesValve SeriesTubing SeriesFitting SeriesProbe SeriesSmart Control Series
Applications
IVD DiagnosticsLife SciencesLaboratory AutomationAnalytical InstrumentsEnvironmental MonitoringSynthetic Biology
Resources
DatasheetsFluid Resistance CalculatorFitting ReplacementInstallation GuidesMaterial CompatibilityTechnical ArticlesCompany News
About Us
About ForeachR&D and ManufacturingQuality System and QualificationsMilestonesForeach Culture
Contact & Partnership
Contact UsBecome a Distributor
  • Pump Series
  • Valve Series
  • Probe Series
  • Fitting Series
  • Tubing Series
  • Control Series
  • IVD
  • Life Science
  • Lab Automation
  • Analytical Instruments
  • Environmental Monitoring
  • Synthetic Biology
  • Datasheets
  • Fluid Resistance Calculator
  • Fitting Replacement
  • Installation Guides
  • Material Compatibility
  • Technical Articles
  • Company News
  • About Foreach
  • R&D & Manufacturing
  • Quality & Compliance
  • History
  • Foreach Culture
  • Inquiry Form
  • Contact Information

Shenzhen Foreach Technology Co., Ltd.

Address: 13th Floor, 2nd Building, Yufengda Industrial Park, 1008th Guang Qiao Boulevard, Guangming District, Shenzhen 518132 CHINAView Map

Email: sales@foreachtek.com

Tel: +86 755 8655 3831

LinkedInYouTubeFacebookInstagramX

© 2026 Shenzhen Foreach Technology Co., Ltd. All rights reserved.

Privacy Policy·

Home/Product Center/Miniature Diaphragm Pumps/DPL60.
DPL60 600 mL/min Miniature Liquid Diaphragm Pump Series

DPL60 600 mL/min Miniature Liquid Diaphragm Pump Series

The Foreach DPL60 series is a miniature liquid diaphragm pump family with 600 mL/min no-load flow, 100 kPa rated pressure, and 3 mH₂O self-priming lift. It is available as the brushed DPL60-DB and brushless DPL60-BB for liquid transfer, washing, line priming, and circulation in compact instruments. Motor life, wiring, and product resources vary by configuration; refer to the corresponding configuration page for exact specifications.

Typical Applications:

Liquid transfer, wash-fluid delivery, line priming, liquid circulation, and instrument fluidics

Model:This product is custom-made
Product typeminiature liquid diaphragm pump series
ConfigurationsDPL60-DB brushed / DPL60-BB brushless
Rated voltageDC 12 V ±10% / DC 24 V ±10%
No-load flow600 mL/min
Rated pressure100 kPa
Self-priming lift3 mH₂O
Working mediumPurified water; other liquids require compatibility evaluation and testing under actual conditions
Wetted materialsPPS pump head; EPDM / PTFE diaphragm; EPDM / FFKM valves
Specified service lifeBrushed 3,000 h / brushless 10,000 h (rated voltage, continuous operation)

2D Drawing Not Available Yet

To request a 2D drawing for this product, please click “Add Drawing” above.

Download DPL60 PDF
Preview DPL60 Datasheet

Frequently Asked Questions

The DPL60 series includes the brushed DPL60-DB and brushless DPL60-BB. They share the same flow and pressure class, while motor life, wiring, and product resources differ.

Specified service life is 3,000 h for the brushed configuration and 10,000 h for the brushless configuration at rated voltage under continuous operation. Final selection should also consider duty cycle, start-stop frequency, control requirements, system resistance, and fluid compatibility.

DPL60 Series Configurations

Choose a configuration page to review its exact motor life, wiring, drawings, and product resources.

DPL60-DB

600 mL/min Brushed DC Miniature Liquid Diaphragm Pump, 3,000 h Service Life, 12 V / 24 V

View DPL60-DB configuration→

DPL60-BB

600 mL/min Brushless DC Miniature Liquid Diaphragm Pump, 10,000 h Service Life, 12 V / 24 V

View DPL60-BB configuration→

Related Videos

View more

Related Technical Articles

Does a Miniature Diaphragm Pump Need a Pulsation Damper? Validate It with an A/B Test

A damper is justified by load performance and its trade-offs in startup, trailing liquid, cleaning and dead volume. Define acceptable ripple at the load, then compare steady operation and start-stop delivery with and without damping under the same task. A smoother trace alone is not a passing result.

2026-09-10View Details

Diaphragm Pump Bubbles and Noise: Cavitation, Air Ingress or Outgassing?

Bubbles, noise and reduced flow do not individually prove cavitation. Separate incoming air, dissolved-gas release and local vapor formation using synchronized absolute inlet pressure, fluid temperature, bubble location and flow. A normal average inlet pressure cannot exclude a brief low-pressure region inside the pump; build evidence through controlled comparisons.

2026-09-10View Details

Why Does a Diaphragm Pump Flow Totalizer Disagree with Collected Mass?

A fluctuating display and an incorrect total are different problems. Match collection windows and hydraulic conditions, convert mass using the real fluid density, then check storage changes, trailing liquid, reverse flow, range and sampling. Only an independent reference can establish whether filtering or damping improves measurement accuracy.

2026-09-10View Details

Foreach miniature diaphragm pumps for OEM integration: operating points, instrument validation and production introduction

Whether the miniature diaphragm pump can work stably in OEM instruments depends on the joint matching of fluid path tasks, inlet and outlet conditions, material combinations, control methods and overall machine structure. Taking Foreach DPL30, DPL60, DPL30H and DPGL800 as examples, this article starts from the flow and pressure budget, gas-liquid status, wetted materials and electrical interfaces to explain how to establish candidate solutions, carry out reproducible prototype verification, and convert the verification results into technical requirements for production supply.

2026-09-11View Details

Selecting a Self-Priming Miniature Liquid Diaphragm Pump: Lift, Priming Time and Dry or Wet Starts

Select a self-priming miniature liquid diaphragm pump by checking suction lift, time to first liquid, dry and wet starting conditions, and stable delivery. Use DPL30, DPL60 and DPL30H specifications to define an instrument-level test.

2026-09-07View Details

Reducing Flow Pulsation in Miniature Diaphragm Pumps: Measurement and Practical Measures

Diagnose miniature diaphragm pump flow pulsation by separating real fluctuations from measurement errors. Compare damping, tubing and speed-control measures using matched operating conditions and endpoint measurements.

2026-09-07View Details

Why do multiple wash nozzles deliver different flows from one miniature diaphragm pump?

Calculate demand from the volume and timing of each wash nozzle, separate insufficient pump output from unequal distribution, and verify each branch with collection and pressure measurements.

2026-09-08View Details

Miniature Diaphragm Pump Noise: Causes, Vibration Isolation and Noise Reduction

Investigate miniature diaphragm pump noise at a matched operating point. Check the motor, pump head, supports, tubing and enclosure, then validate noise-reduction measures against flow, temperature rise and reliability.

2026-09-07View Details

Flow starts normally, then falls: how do you check reservoir venting for a miniature diaphragm pump?

Record reservoir headspace pressure, pump inlet pressure and delivery together to investigate restricted venting and distinguish liquid-level changes, blockage, air leaks and outlet backpressure.

2026-09-08View Details

Miniature Diaphragm Pump Backflow After Stopping: Check Valves and Anti-Siphon Design

Diagnose reverse flow after a miniature diaphragm pump stops, distinguish it from forward siphoning and residual dripping, and evaluate check-valve behavior, valve sequencing and static sealing in the complete circuit.

2026-09-07View Details

Which Materials Are Available for Miniature Diaphragm Pumps? Selection Considerations

Compare pump-head, diaphragm and valve materials, then check fluid composition, concentration, temperature, exposure time and cleaning conditions before selecting a configuration.

2026-09-07View Details

What Is the Difference Between an Ink Circulation Pump, Ink Supply Pump and Ink Return Pump?

Ink supply pump, ink return pump and ink circulation pump are fluidic functions, not three fixed mechanical pump types. A supply pump moves ink toward a sub-tank or printhead, a return pump moves unused ink back toward a reservoir, and a circulation pump maintains flow around a loop. Whether those functions need one, two or several pumps depends on the printhead, reservoirs, gravity or vacuum control, filters and supply-return architecture.

2026-09-03View Details

300 or 600 mL/min? How to Select an Ink Circulation or Ink Return Pump

Define the target working flow in the ink circulation or return circuit, then calculate or measure system differential pressure at that flow. The DPL30 300 mL/min and DPL60 600 mL/min values are no-load flow classes, not guaranteed flow after adding ink, filters, tubing and a printhead. The closer the target is to the nominal limit, the more important curve and installed testing become.

2026-09-03View Details

Why Is White Ink Recirculation More Difficult, and How Should a White Ink Circulation Pump Be Selected?

White ink normally uses high-refractive-index, high-specific-gravity pigment for opacity. TiO₂ is common, but density difference, dispersion, agglomeration and idle time affect settling. The objective is not simply a larger pump flow. The reservoir, tubing, filter and printhead region need controlled flow that reaches critical dead zones while respecting printhead pressure, ink condition and material compatibility.

2026-09-03View Details

How to Select an IVD Waste Liquid Pump: Liquid or Gas-Liquid Diaphragm Pump?

Do not select an IVD waste pump from mL/min alone. If the line remains liquid-filled and transfers waste continuously, evaluate a liquid diaphragm pump. If the aspiration needle ingests air and the inlet alternates between liquid and gas, evaluate a gas-liquid diaphragm pump together with vacuum, system volume and evacuation time.

2026-09-03View Details

What Are Cleaning, Wash and Rinse Pumps in IVD Systems, and Why Are Miniature Diaphragm Pumps Used?

Cleaning pump, wash pump and rinse pump usually name different duties within an IVD cleaning sequence, not three fixed pump mechanisms. Selection starts with wash volume, cycle rate, line resistance, wetted materials, and whether the duty is liquid supply or waste aspiration.

2026-09-03View Details

How Do You Choose Between a 300 mL/min and 600 mL/min Miniature Diaphragm Pump? Calculate Task Flow First, Then Check the Actual Operating Point

The 300 mL/min and 600 mL/min values are flow classes first, not fixed outputs after installation in an instrument. Selection should begin by converting the liquid-handling task into a minimum average flow rate, then determining the differential pressure required by the actual fluid path, and finally confirming the operating point on the pump curve and in prototype testing.

2026-08-30View Details

Why Does Actual Flow Change So Much When the Tubing Size Changes on the Same Miniature Diaphragm Pump?

Even when the pump is unchanged, installed flow can change because of tubing inner diameter, length, bends, and the minimum bore of fittings. When flow falls after a tubing change, the effective response is neither to blame the pump first nor to enlarge every tube indiscriminately. Measure inlet pressure, outlet pressure, and accumulated flow together to determine where the added restriction actually occurs.

2026-08-24View Details

Which Has a Greater Effect on a Miniature Diaphragm Pump: Suction-Line or Discharge-Line Resistance?

Pressure loss on either the suction or discharge side increases the differential pressure carried by a miniature diaphragm pump, but there is no universal rule that one side is always more important. The suction side more readily affects initial priming, chamber filling, sensitivity to air leakage, outgassing, and cavitation. The discharge side more often appears as increased backpressure, reduced flow, and deadheading. Diagnose the system by observing inlet absolute pressure, outlet pressure, and flow on the same time axis.

2026-08-21View Details

What Is the Difference Between Rated Working Pressure, Maximum Output Pressure, Proof Pressure, and Burst Pressure for a Miniature Diaphragm Pump?

A pressure value has engineering meaning only when it is paired with a term definition, test fluid, inlet condition, corresponding flow rate, duration, and acceptance criteria. Rated working pressure can define an operating boundary; maximum output pressure, proof-test pressure, and burst pressure cannot be treated directly as continuous operating points.

2026-08-18View Details

Is 100 kPa Enough? How to Determine Whether a Fluid Path Needs a 600 kPa High-Pressure Miniature Diaphragm Pump

100 kPa and 600 kPa are not simply a standard version and an upgraded version. First complete a pressure budget for the entire fluid path at the target flow, then read the candidate pump curve. A higher pressure rating has value only when the application truly has high backpressure.

2026-08-15View Details

Why Do Brushed Diaphragm Pumps Last Around 3,000 Hours and Brushless Pumps Around 10,000 Hours?

Brushed miniature diaphragm pumps commonly have a reference life of approximately 3,000 hours; brushless versions are often rated around 10,000 hours. The difference reflects commutation, dominant wear mechanisms and the actual duty profile rather than a simple motor-quality ranking.

2026-08-03View Details

How to Select a Miniature Diaphragm Pump for Life-Science Instruments: DPL60 Washing, Drainage and Waste-Fluid Guide

Life-science instruments need more than accurate sample dispensing: they also wash reaction chambers, flush tubing, remove waste, prime lines and circulate liquid. Reliable diaphragm-pump selection depends on complete fluid-path resistance, suction conditions, wetted materials and long-term duty rather than catalog maximum flow alone.

2026-07-31View Details

How to Read a Diaphragm Pump Flow-Pressure Curve—and Predict Installed Flow

A catalogue value such as 300 or 600 mL/min is not a fixed flow rate inside an instrument. The useful engineering question is: at the actual inlet pressure, outlet backpressure, fluid, tubing and supply voltage, where will the pump and the fluidic circuit settle?

2026-07-28View Details

How Long Can a Miniature Diaphragm Pump Run Continuously? A Duty-Cycle and Life Guide

A pump described as suitable for continuous operation is not a pump with unlimited life. Continuous-duty capability, accumulated service life, calendar life and statistical reliability answer different engineering questions—and all depend on the stated load, fluid, electrical drive and environment.

2026-07-25View Details

2-Wire vs 5-Wire Brushless Diaphragm Pumps: What Is the Difference and Which Should You Choose?

When selecting a miniature diaphragm pump, two lead configurations may be offered for the same type of DC brushless motor: 2-wire and 5-wire. The main difference is not the pump's basic delivery principle, but how much control and operating-status information the equipment requires from the motor.

2026-07-22View Details

How to Select a 600 mL/min Liquid Diaphragm Pump: DPL60 Flow, Pressure and Model Guide

The DPL60 is Foreach's miniature liquid diaphragm pump for higher-flow instrument circuits. It is intended for washing, flushing, circulation, larger-volume transfer and waste-liquid removal where liquid exchange must be faster than in a 300 mL/min-class circuit.

2026-07-13View Details

Need help selecting a diaphragm pump?

Share the fluid, flow rate, pressure, self-priming requirements, wetted materials, port type, and installation space. The Foreach engineering team can help confirm a suitable diaphragm pump configuration.

Contact an Engineer