MEDICA 2026Foreach Booth 1H39-1Medical Trade Fair in Düsseldorf, GermanyDüsseldorfNov 16–19
Learn MoreBook a Meeting
Foreach TechnologyForeach Technology
Home
Products
Applications
About Us
Contact & Partnership
简体中文EnglishEspañolFrançais한국어Русский
Home
Products
Pump SeriesValve SeriesTubing SeriesFitting SeriesProbe SeriesSmart Control SeriesTubing Assemblies
Applications
All applicationsIVD DiagnosticsLife SciencesLaboratory AutomationAnalytical InstrumentsEnvironmental MonitoringSynthetic Biology
Resources
Frequently Asked QuestionsDatasheetsFluid Resistance CalculatorFitting ReplacementInstallation GuidesMaterial CompatibilityTechnical ArticlesCompany News
About Us
About ForeachR&D and ManufacturingQuality System and QualificationsMilestonesForeach Culture
Contact & Partnership
Contact UsBecome a Distributor
  • Pump Series
  • Valve Series
  • Probe Series
  • Fitting Series
  • Tubing Series
  • Control Series
  • Tubing Assemblies
  • All applications
  • IVD
  • Life Science
  • Lab Automation
  • Analytical Instruments
  • Environmental Monitoring
  • Synthetic Biology
  • Frequently Asked Questions
  • Datasheets
  • Fluid Resistance Calculator
  • Fitting Replacement
  • Installation Guides
  • Material Compatibility
  • Technical Articles
  • Company News
  • About Foreach
  • R&D & Manufacturing
  • Quality & Compliance
  • History
  • Foreach Culture
  • Inquiry Form
  • Contact Information

Shenzhen Foreach Technology Co., Ltd.

Address: 13th Floor, 2nd Building, Yufengda Industrial Park, 1008th Guang Qiao Boulevard, Guangming District, Shenzhen 518132 CHINAView Map

Email: sales@foreachtek.com

Tel: +86 755 8655 3831

LinkedInYouTubeFacebookInstagramX

© 2026 Shenzhen Foreach Technology Co., Ltd. All rights reserved.

Privacy Policy·

Home/Product Center/Tubing Assemblies/Ferrule Tubing Assemblies/PFA Ferrule Tubing Assembly
Front angled view of a PFA ferrule tubing assembly showing the translucent threaded fitting, ferrule bore and clear tubing

PFA Ferrule Tubing Assembly

FOREACH PFA ferrule tubing assemblies combine PFA tubing, matching fittings and ferrules. The compressed ferrule connects the instrument port without pre-flanging the tube end. They can connect reagent, cleaning-fluid and internal fluid paths in in-vitro diagnostic (IVD) and automated analytical instruments. Reference tubing OD is 1.6 mm, with IDs of 0.5, 0.8 or 1.0 mm. Specify length and both end connections in the drawing.

Standard flat-bottom port threads include M6×1 and 1/4-28 UNF. Select fitting materials and PP or ETFE ferrules for the model, tube size and operating conditions, confirming compatibility among tubing, ferrule and port. Define A/B fitting structures, threads and materials separately and specify protective sleeves, stop tubes, identification or coils as needed. Samples and batch assembly are supported. Confirm working pressure and temperature for the specific dimensions, ports and complete assembly.

FOREACH holds ISO 9001 and ISO 13485 quality management system certifications.

Typical Applications:

PFA reagent line connections, End connections for 1.6 mm OD tubing, Fluid connections without pre-flanging, Instrument tubing assembly

Product DatasheetFull Product Catalog
Tubing material and appearancePFA
Connection structureFerrule connection; no tube pre-flanging required
Fitting structureStandard, compact
Fitting materialPPS, PVDF, PEEK, POM, PP; selected by series
Thread sizesM6×1, 1/4-28 UNF
Ferrule materialPP, ETFE; matched to the model
Finished lengthCustom to drawing, with specified length and tolerance
A/B endsFitting material, thread and connection type can be specified separately
Optional configurationsCoils, abrasion protection sleeves, stop tubes, heat-shrink labels

Tube Size Combinations

PFA
Tube OD (mm)Matching Tube ID (mm)
1.60.5 / 0.8 / 1.0

These are available tubing sizes. Confirm end dimensions and mating ports against the assembly drawing.

Match fitting material, structure and thread to the corresponding model.

Working pressure and temperature must be confirmed for the specific assembly configuration.

Matching fittings and 2D drawings

The table lists fitting series, threads and body materials for 1.6 mm tube OD as examples. Select the drawing by material and full model number; confirm matching parts for other ODs during customization.

Fitting seriesThread sizeNut materialFitting drawing
HNM6×1PVDF, PPS, PEEK, POM
PVDF · PDFHN-M6-16-PV-NPPS, PEEK, POM · PDFHN-M6-16-PS-B
HN1/4-28 UNFPVDF, PPS, PEEK, POMConfirm for the selected model
HNFM6×1PVDF
View PDFHNF-M6-16-PV-N
HNF1/4-28 UNFPVDF
View PDFHNF-U28-16-PV-N
HN6M6×1PVDF, PPS, PEEK, POM
View PDFHN6-M6-16-PV-N
HN61/4-28 UNFPVDF, PPS, PEEK, POM
View PDFHN6-U28-16-PV-N
HNF6M6×1PPS
View PDFHNF6-M6-16-PS-B
HNF61/4-28 UNFPPS
View PDFHNF6-U28-16-PS-B

Frequently Asked Questions

The currently listed reference OD is 1.6 mm, with 0.5, 0.8 or 1.0 mm ID. For other sizes, provide a drawing so an engineer can review tubing availability and end connections.

Specify finished length and tolerance, A/B fittings and threads, and the positions of sleeving, stop tubes and identification to suit the routing. Connection components are matched to the tube dimensions and ports.

No. The matching fitting compresses the ferrule to retain and seal the tubing. Follow the model-specific requirements for ferrule orientation, tube insertion depth and tightening.

Pressure depends on tubing, dimensions, temperature, connections and assembly. Provide the target pressure and fluid; use the confirmed rating and test report for that configuration.

Related Technical Articles

What Is a Flangeless Ferrule Fitting? Design, Sizes and Selection

Flangeless fittings use a threaded nut to compress a ferrule around rigid tubing, without preforming a flange. FOREACH HN, HN6, HNF and HNF6 cover tubing ODs of 1.6, 2.0, 2.5, 3.0 and 3.2 mm, M6×1 and 1/4-28 UNF threads, and several nut materials for reagent transfer, sample handling and wash lines in analytical instruments and laboratory automation.

2026-10-13View Details

Microfluidic Hard-Tube Fitting Selection Guide: Flanged, Ferrule and Snap-Ring Connections

Selection essentials: Check port geometry, tubing OD and fluid first, then pressure, maintenance frequency and tube-end preparation. Flanged fittings press a tube-end flange against a flat sealing face; ferrules grip the tube as the fitting tightens; snap-ring designs use a sleeve and sealing ring. Matching threads and tube diameters alone do not establish compatibility.

2026-10-12View Details

Submit your requirements

Prepare an assembly drawing, port drawing or BOM, together with sample quantity, batch requirements and acceptance criteria.

Customization Request