MEDICA 2026Foreach Booth 1H39-1Medical Trade Fair in Düsseldorf, GermanyDüsseldorfNov 16–19
Learn MoreBook a Meeting
Foreach TechnologyForeach Technology
Home
Products
Applications
About Us
Contact & Partnership
简体中文EnglishEspañolFrançais한국어Русский
Home
Products
Pump SeriesValve SeriesTubing SeriesFitting SeriesProbe SeriesSmart Control SeriesTubing Assemblies
Applications
All applicationsIVD DiagnosticsLife SciencesLaboratory AutomationAnalytical InstrumentsEnvironmental MonitoringSynthetic Biology
Resources
Frequently Asked QuestionsDatasheetsFluid Resistance CalculatorFitting ReplacementInstallation GuidesMaterial CompatibilityTechnical ArticlesCompany News
About Us
About ForeachR&D and ManufacturingQuality System and QualificationsMilestonesForeach Culture
Contact & Partnership
Contact UsBecome a Distributor
  • Pump Series
  • Valve Series
  • Probe Series
  • Fitting Series
  • Tubing Series
  • Control Series
  • Tubing Assemblies
  • All applications
  • IVD
  • Life Science
  • Lab Automation
  • Analytical Instruments
  • Environmental Monitoring
  • Synthetic Biology
  • Frequently Asked Questions
  • Datasheets
  • Fluid Resistance Calculator
  • Fitting Replacement
  • Installation Guides
  • Material Compatibility
  • Technical Articles
  • Company News
  • About Foreach
  • R&D & Manufacturing
  • Quality & Compliance
  • History
  • Foreach Culture
  • Inquiry Form
  • Contact Information

Shenzhen Foreach Technology Co., Ltd.

Address: 13th Floor, 2nd Building, Yufengda Industrial Park, 1008th Guang Qiao Boulevard, Guangming District, Shenzhen 518132 CHINAView Map

Email: sales@foreachtek.com

Tel: +86 755 8655 3831

LinkedInYouTubeFacebookInstagramX

© 2026 Shenzhen Foreach Technology Co., Ltd. All rights reserved.

Privacy Policy·

Home/Product Center/Tubing Assemblies/Flanged Tubing Assemblies/PFA Flanged Tubing Assembly
PFA flanged tubing assembly with a transparent flanged end, translucent threaded fitting and metal support washer

PFA Flanged Tubing Assembly

FOREACH PFA flanged tubing assemblies combine PFA tubing, threaded fittings and matching washers for reagent, cleaning-fluid and internal connections in in-vitro diagnostic (IVD) and automated analytical instruments. Reference tubing OD is 1.6 mm, with IDs of 0.5, 0.8 or 1.0 mm. Specify finished length and single- or double-ended connections; confirm flange forming and mating ports against the drawing.

PPS, PVDF or PEEK fittings are selected for the configuration, with standard threads including M6×1 and 1/4-28 UNF. Define each A/B fitting, thread and connection separately and specify protective sleeves, stop tubes, identification or coils as required. Matching is evaluated against tube dimensions, face-seal geometry and fluid. Equipment development, samples and batch assembly are supported. Confirm working pressure and temperature for the specific dimensions, ports and complete assembly.

FOREACH holds ISO 9001 and ISO 13485 quality management system certifications.

Typical Applications:

PFA reagent line connections, Cleaning-fluid line integration, Internal instrument fluid connections, Tubing made to drawing

Product DatasheetFull Product Catalog
Tubing material and appearancePFA
Tube endsSingle- or double-flanged ends
Fitting structureStandard, compact
Fitting materialPPS, PVDF, PEEK
Standard threadsM6×1, 1/4-28 UNF
Support washersMaterial and size matched to the fitting model
Finished lengthCustom to drawing, with specified length and tolerance
A/B endsFitting material, thread and connection type can be specified separately
Optional configurationsCoils, abrasion protection sleeves, stop tubes, heat-shrink labels

Tube Size Combinations

PFA
Tube OD (mm)Matching Tube ID (mm)
1.60.5 / 0.8 / 1.0

These are available tubing sizes. Confirm flange dimensions and mating ports against the assembly drawing.

Match fitting material, structure and thread to the corresponding model.

Miniature option: 6-40 UNF, PEEK fitting, 1.6 mm tube OD. Confirm the complete end configuration against the selected model.

Working pressure and temperature must be confirmed for the specific assembly configuration.

Matching fittings and 2D drawings

The table lists fitting series, threads and body materials for 1.6 mm tube OD as examples. Select the drawing by material and full model number; confirm matching parts for other ODs during customization.

Fitting seriesThread sizeNut materialFitting drawing
HFM6×1PVDF, PPS, PEEKConfirm for the selected model
HF1/4-28 UNFPVDF, PPS, PEEK
View PDFHF-U28-20-PV-N
HFLM6×1PVDF
View PDFHFL-M6-16-PV-N
HFL1/4-28 UNFPVDF
View PDFHFL-U28-16-PV-N
HF6M6×1PVDF, PPS, PEEK
View PDFHF6-M6-20-PV-N
HF61/4-28 UNFPVDF, PPS, PEEK
View PDFHF6-U28-20-PV-N
HFL6M6×1PPS
View PDFHFL6-M6-16-PS-B
HFL61/4-28 UNFPPS
View PDFHFL6-U28-16-PS-B
HFL66-40 UNFPEEK
View PDFHFL6-U40-16-PK-N

Frequently Asked Questions

The currently listed reference OD is 1.6 mm, with 0.5, 0.8 or 1.0 mm ID. For other sizes, provide a drawing so an engineer can review tubing availability and end connections.

Specify finished length and tolerance, A/B fittings and threads, and the positions of sleeving, stop tubes and identification to suit the routing. Connection components are matched to the tube dimensions and ports.

Specify flanging at one or both ends, and define the fitting material, thread and connection type for A/B separately. For a single-flanged assembly, specify the other end connection on the drawing.

Pressure depends on tubing, dimensions, temperature, connections and assembly. Provide the target pressure and fluid; use the confirmed rating and test report for that configuration.

Related Technical Articles

How to Select Flanged Tubing Assemblies: Sealing, Port Matching and Installed Validation

Select tubing material, ID and OD, both end fittings, backing washers, port geometry and installation dimensions together. Confirm that the flange is correctly compressed against the flat-bottom port, then specify retainers, labels and installed validation.

2026-10-12View Details

Microfluidic Hard-Tube Fitting Selection Guide: Flanged, Ferrule and Snap-Ring Connections

Selection essentials: Check port geometry, tubing OD and fluid first, then pressure, maintenance frequency and tube-end preparation. Flanged fittings press a tube-end flange against a flat sealing face; ferrules grip the tube as the fitting tightens; snap-ring designs use a sleeve and sealing ring. Matching threads and tube diameters alone do not establish compatibility.

2026-10-12View Details

Submit your requirements

Prepare an assembly drawing, port drawing or BOM, together with sample quantity, batch requirements and acceptance criteria.

Customization Request