MEDICA 2026Foreach Booth 1H39-1Medical Trade Fair in Düsseldorf, GermanyDüsseldorfNov 16–19
Learn MoreBook a Meeting
Foreach TechnologyForeach Technology
Home
Products
Applications
About Us
Contact & Partnership
简体中文EnglishEspañolFrançais한국어Русский
Home
Products
Pump SeriesValve SeriesTubing SeriesFitting SeriesProbe SeriesSmart Control SeriesTubing Assemblies
Applications
All applicationsIVD DiagnosticsLife SciencesLaboratory AutomationAnalytical InstrumentsEnvironmental MonitoringSynthetic Biology
Resources
Frequently Asked QuestionsDatasheetsFluid Resistance CalculatorFitting ReplacementInstallation GuidesMaterial CompatibilityTechnical ArticlesCompany News
About Us
About ForeachR&D and ManufacturingQuality System and QualificationsMilestonesForeach Culture
Contact & Partnership
Contact UsBecome a Distributor
  • Pump Series
  • Valve Series
  • Probe Series
  • Fitting Series
  • Tubing Series
  • Control Series
  • Tubing Assemblies
  • All applications
  • IVD
  • Life Science
  • Lab Automation
  • Analytical Instruments
  • Environmental Monitoring
  • Synthetic Biology
  • Frequently Asked Questions
  • Datasheets
  • Fluid Resistance Calculator
  • Fitting Replacement
  • Installation Guides
  • Material Compatibility
  • Technical Articles
  • Company News
  • About Foreach
  • R&D & Manufacturing
  • Quality & Compliance
  • History
  • Foreach Culture
  • Inquiry Form
  • Contact Information

Shenzhen Foreach Technology Co., Ltd.

Address: 13th Floor, 2nd Building, Yufengda Industrial Park, 1008th Guang Qiao Boulevard, Guangming District, Shenzhen 518132 CHINAView Map

Email: sales@foreachtek.com

Tel: +86 755 8655 3831

LinkedInYouTubeFacebookInstagramX

© 2026 Shenzhen Foreach Technology Co., Ltd. All rights reserved.

Privacy Policy·

Home/Product Center/Valves/SV10 Solenoid Valves/SV10-B16-2NO
FOREACH SV10-B16-2NO 2-way normally open barbed miniature diaphragm solenoid valve

Normally Open 2-Way Micro Diaphragm Solenoid Valve SV10-B16-2NO, Barbed Ports for Medical and Laboratory Instruments

The SV10-B16-2NO is a normally open micro diaphragm solenoid valve with 2-way operation and barbed tubing ports. Its compact rocker design and low dead volume help reduce retained liquid and provide precise on/off control. The valve opens when de-energized and closes when energized, suiting supply or wash branches that normally remain open and are temporarily closed by the program in laboratory instruments and automated liquid-handling equipment.

The barbed ports are recommended for flexible tubing with a 1.5–2.0 mm internal diameter, allowing tubing to be routed around pumps, detection modules and reservoirs. Plan the mounting position around tubing bend space and maintenance access; a custom bracket can be provided as needed. Select EPDM, FKM or FFKM diaphragms and matching O-rings with both the delivered liquids and the cleaning fluids in mind.

Application Areas:

IVD, Laboratory Automation, Analytical Instruments

SV10-B16-2NO configurations

Select the required options (Rated Voltage, Diaphragm Material, Base-Plate Material, and Power-Saving Circuit) and save the configuration for your inquiry.

Product DatasheetFull Product Catalog
Configuration family (not a complete ordering code)SV10-B16-2NO
Valve structureRocker diaphragm valve
Ports and function2-way normally open (NO)
ConnectionBarbed; tubing ID 1.5–2.0 mm
Operating pressure-75 kPa – 0.25 MPa
Orifice diameter1.4 mm
Chamber volume20 μL
Flow coefficient Cv0.03
Diaphragm and O-ring optionsEPDM / FKM / FFKM
Base platePEEK
Rated voltageDC 12 / 24 V (±10%)
Standard power2.5 W
Power-saving circuitStart: 2.5 W; hold: ≤1 W
Standard response time≤15 ms, no load
Power-saving response time≤25 ms, no load
Ambient temperature0–50 °C
Fluid temperature0–50 °C, non-freezing
Coil insulationF
Weight29 g
Response test conditions25 °C, rated voltage, maximum operating pressure with air, common port pressurized. Response varies with fluid, pressure, tubing and temperature.

Typical Applications

Normally Open 2-Way Micro Diaphragm Solenoid Valve SV10-B16-2NO, Barbed Ports for Medical and Laboratory Instruments

2-way solenoid valves for reagent on/off control

In an automated analyzer, a 2-way valve can open the reagent line for a dispensing step and close it afterwards. Choose NC when the connection must be closed without power, or NO when it must remain open.

Coordinate the valve with the pump and equipment program. The valve controls the connection; the pump and its operating sequence determine the amount delivered.

Power-off behavior: normally closed or normally open

The normally open valve is open when de-energized and closes when energized. Use it for fluid paths that must remain open when power is off. The valve controls the connection; a pump or pressure difference drives the liquid.

Equipment integration: manifold or tubing connections

Use the base-mounted version when combining valves on a fluidic manifold. Choose threaded connections for tube fittings, or barbed connections for flexible tubing.

Plan access for installation, tubing replacement and wiring. The three connection styles serve different layouts while retaining the same choices of 2-way or 3-way function.

Tell us about your application

Describe which liquid must flow at each step and what should happen when power is removed. Include the connection drawing, fluids, pressure, temperature, supply voltage and installation space.

Compare 2-way and 3-way solenoid valves

All SV10 solenoid valves
3-Way Manifold-Mount
3-Way Barbed
3-Way Threaded
2-Way Manifold-Mount
2-Way Barbed
2-Way Threaded
2-Way Manifold-Mount, Normally Open
2-Way Threaded, Normally Open

3D Model

Technical Drawing

Download 6010 Solenoid Valve Datasheet PDF
Preview 6010 Solenoid Valve Datasheet Datasheet

Frequently Asked Questions

The normally open valve is open when de-energized and closes when energized. Use it for fluid paths that must remain open when power is off. The valve controls the connection; a pump or pressure difference drives the liquid.

Choose the valve according to what your equipment needs when power is removed. A normally closed solenoid valve closes the connection without power and opens it when energized. A normally open solenoid valve does the reverse. The SV10 series offers NC and NO options for its 2-way valves.

Provide the reagent and cleaning-fluid composition, concentration, temperature and contact time. Check all wetted parts together: diaphragm, O-rings, base plate and, on threaded versions, the valve seat. A material name alone does not establish compatibility with every fluid.

Standard power is 2.5 W; the optional power-saving circuit uses 2.5 W at start and no more than 1 W while holding. Observe polarity: red positive, black negative.

Response is ≤15 ms for the standard version and ≤25 ms with the power-saving circuit under no-load test conditions at 25 °C, rated voltage and maximum operating air pressure applied to the common port. Actual timing varies with the circuit and fluid. FFKM diaphragms respond more slowly at temperatures of 15 °C or below.

Send the circuit diagram, 2-way or 3-way requirement, unpowered state, connection type, reagent and cleaning fluids, pressure, temperature and supply voltage. Include mounting space and cycle timing so we can match the connection, materials and power-saving option. The displayed models identify configuration families, not complete ordering codes. Confirm the operating state, voltage, diaphragm and other wetted materials, and power-saving option when ordering. M6 and U28 identify separate M6 and 1/4-28 UNF threaded versions.

Related Videos

SV10 Miniature Solenoid Valves: Product Overview

SV10

Related Technical Articles

What Is a Solenoid Valve? Operating Principles and 2-Way/3-Way Fluid Control

Follow the fluid path after energization to understand how 2-way and 3-way solenoid valves handle reagent dispensing and washing, and how they work with pumps and control programs.